Rant: spent 4 hours chasing a leak on a wet bell panel that was just a loose hose clamp
Had a wet bell job off the Sara Bordelon near Fourchon last Tuesday and the panel kept showing a low air alarm. I pulled the regulator apart twice, swapped gauges, and had the tender check the umbilical fittings, which ate up 4 hours of dive time. Turned out the clamp on the return line was hand tight and letting air past the seal the whole time. Any of you run into a false alarm that turned out to be something that dumb?